Voordeelbundel
BICSI BUNDLE/ LATEST UPDATE
BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. BICSI IN225 7, BICSI IN250 BICSI TDMM12 BICSI OSP BICSI Installer 2
[Meer zien]BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. BICSI IN225 7, BICSI IN250 BICSI TDMM12 BICSI OSP BICSI Installer 2
[Meer zien]BICSI Installer 1, Top Questions and answers, 100% Accurate. Graded A+ 
 
 
25-pair color code - -White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, b...
Voorbeeld 3 van de 17 pagina's
In winkelwagenBICSI Installer 1, Top Questions and answers, 100% Accurate. Graded A+ 
 
 
25-pair color code - -White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, b...
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
B 
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C...
Voorbeeld 4 van de 49 pagina's
In winkelwagenBICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
BICSI - Installer 1 – Exam Review Questions and answers, 100% Accurate. Graded A+ 
B 
A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C...
BICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is ...
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Practice Test-RETAKE. Top Exam Questions and answers. Latest update. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is ...
BICSI ITSMM, Top Exam Questions and 
answers. 100% Accurate. Graded A+
Voorbeeld 2 van de 8 pagina's
In winkelwagenBICSI ITSMM, Top Exam Questions and 
answers. 100% Accurate. Graded A+
BICSI Exam Review Questions and answers, 100% Accurate, rated A+
Voorbeeld 2 van de 12 pagina's
In winkelwagenBICSI Exam Review Questions and answers, 100% Accurate, rated A+
BICSI RTPM, Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
design and implementation/installation - -Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - -Review expression of interest for client 
Perform a user needs analysis...
Voorbeeld 4 van de 41 pagina's
In winkelwagenBICSI RTPM, Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
design and implementation/installation - -Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - -Review expression of interest for client 
Perform a user needs analysis...
BICSI Installer 2: Fiber Module. Top Exam Questions and answers. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz 
 
One millio...
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Installer 2: Fiber Module. Top Exam Questions and answers. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz 
 
One millio...
BICSI IN250 Optical Fiber Review Questions and answers. 100% Accurate. VERIFIED. 
 
 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - -Survey the Scene 
 
When Surveying a Victim wh...
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI IN250 Optical Fiber Review Questions and answers. 100% Accurate. VERIFIED. 
 
 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - -Survey the Scene 
 
When Surveying a Victim wh...
BICSI IN250 Optical Fiber Review 
Questions and answers. 100% Accurate. 
VERIFIED. 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
What is the 1st step you should take to safely assist an injured person during an emergency? - - 
Survey the Scene
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI IN250 Optical Fiber Review 
Questions and answers. 100% Accurate. 
VERIFIED. 
SAFETY REVIEW 
OSHA - -Occupational Safety and Health Administration 
What is the 1st step you should take to safely assist an injured person during an emergency? - - 
Survey the Scene
BICSI Technician HW #2. Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, mis...
Voorbeeld 1 van de 4 pagina's
In winkelwagenBICSI Technician HW #2. Top Exam Questions and answers, 100% Accurate. VERIFIED. 
 
 
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, mis...
BICSI Installer 2, Top Exam Questions & Answers, 100% Accurate. 
 
 
1 
KEY TERMS 
 
Choose Correct Term: 
 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 1...
Voorbeeld 4 van de 91 pagina's
In winkelwagenBICSI Installer 2, Top Exam Questions & Answers, 100% Accurate. 
 
 
1 
KEY TERMS 
 
Choose Correct Term: 
 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 1...
BICSI 1 & 2, Top Exam Questions & Answers, 100% Accurate. Rated A+ 
 
 
TIA/EIA - -Telecommunications Industry Association / Electronic Industries Alliance 
 
TIA/EIA-568-C.0 - -Generic Telecommunications Cabling for Customer Premises 
 
TIA-568-C.1 - -Commercial Building Telecommunications Cabling ...
Voorbeeld 3 van de 28 pagina's
In winkelwagenBICSI 1 & 2, Top Exam Questions & Answers, 100% Accurate. Rated A+ 
 
 
TIA/EIA - -Telecommunications Industry Association / Electronic Industries Alliance 
 
TIA/EIA-568-C.0 - -Generic Telecommunications Cabling for Customer Premises 
 
TIA-568-C.1 - -Commercial Building Telecommunications Cabling ...
BICSI IN225 7.0, Installer 2, Copper. Exam Review Question Sections & Answers. Rated A+ 
 
 
Attenuation - -The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - -Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - -The numerical system for designating wire diameter....
Voorbeeld 4 van de 33 pagina's
In winkelwagenBICSI IN225 7.0, Installer 2, Copper. Exam Review Question Sections & Answers. Rated A+ 
 
 
Attenuation - -The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - -Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - -The numerical system for designating wire diameter....
BICSI chapter 5. Top Exam Questions & Answers, 100% Accurate. 
 
 
high pair count cable can be loaded onto reels that are up too - -2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - -knowledge of industry standards and codes 
understanding th...
Voorbeeld 1 van de 4 pagina's
In winkelwagenBICSI chapter 5. Top Exam Questions & Answers, 100% Accurate. 
 
 
high pair count cable can be loaded onto reels that are up too - -2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - -knowledge of industry standards and codes 
understanding th...
BICSI Installer 2, Copper, Chapter 1, Balanced Twisted Pair Cable. Top Exam Questions & Answers, Rated A+ 
 
 
Balanced twisted-pair cables have a nominal characteristic impedance of - -100 ohms at 100 MHz 
 
Insulation - -Copper wires must be physically separated 
 
UTP - -unshielded twisted-pair 
...
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Installer 2, Copper, Chapter 1, Balanced Twisted Pair Cable. Top Exam Questions & Answers, Rated A+ 
 
 
Balanced twisted-pair cables have a nominal characteristic impedance of - -100 ohms at 100 MHz 
 
Insulation - -Copper wires must be physically separated 
 
UTP - -unshielded twisted-pair 
...
BICSI Installer 2, Copper, Chapter 2. Top 
Exam Questions and answers, 100% 
Accurate. Rated A+
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Installer 2, Copper, Chapter 2. Top 
Exam Questions and answers, 100% 
Accurate. Rated A+
Systems Verification BICSI Final, Top Exam Questions & Answers, Graded A+
Voorbeeld 4 van de 35 pagina's
In winkelwagenSystems Verification BICSI Final, Top Exam Questions & Answers, Graded A+
BICSI chapter 4, Top Exam Questions & Answers, 100% Accurate, rated A+ 
 
 
In the absence of a specified distance, what is the minimum space front and back for work area? - -Minimum of, 3.3 feet front and back workspace.
Voorbeeld 1 van de 4 pagina's
In winkelwagenBICSI chapter 4, Top Exam Questions & Answers, 100% Accurate, rated A+ 
 
 
In the absence of a specified distance, what is the minimum space front and back for work area? - -Minimum of, 3.3 feet front and back workspace.
BICSI's ICT Terminology Handbook (Version 1.0). Exam Questions & Answers, rated A+ 
 
 
Administration - -The method for labeling, documentation, and usage needed to implement moves, additions, and changes of the telecommunications infrastructure. 
 
Alien Crosstalk - -A measure of the unwanted sig...
Voorbeeld 2 van de 5 pagina's
In winkelwagenBICSI's ICT Terminology Handbook (Version 1.0). Exam Questions & Answers, rated A+ 
 
 
Administration - -The method for labeling, documentation, and usage needed to implement moves, additions, and changes of the telecommunications infrastructure. 
 
Alien Crosstalk - -A measure of the unwanted sig...
BICSI Technician- Netcom - Chapter 1 exam Questions & Answers, rated A+ 
 
 
Three transmission methods are - -Symplex, half duplex, full duplex
Voorbeeld 3 van de 17 pagina's
In winkelwagenBICSI Technician- Netcom - Chapter 1 exam Questions & Answers, rated A+ 
 
 
Three transmission methods are - -Symplex, half duplex, full duplex
1x verkocht
BICSI OSP, Exam Review Questions & Answers, 100% Accurate. VERIFIED. 
 
 
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - -One SIze Larger
Voorbeeld 2 van de 12 pagina's
In winkelwagenBICSI OSP, Exam Review Questions & Answers, 100% Accurate. VERIFIED. 
 
 
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - -One SIze Larger
BICSI Exam Questions and answers. Graded A+/ latest updates. 
 
 
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - False (describes Codes) 
 
A _____...
Voorbeeld 1 van de 4 pagina's
In winkelwagenBICSI Exam Questions and answers. Graded A+/ latest updates. 
 
 
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - False (describes Codes) 
 
A _____...
BICSI Installer 2: Fiber Module. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Installer 2: Fiber Module. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Code - -Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - -National electric code 
 
Frequency conversion chart - -One thousand hertz = 1KHz
BICSI TDMM12 Chapter 12 Top Exam Questions & Answers, 100% Accurate. 
 
 
*Figure 12.1-Pic on test-Transposed pairs - -2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - -A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooti...
Voorbeeld 1 van de 2 pagina's
In winkelwagenBICSI TDMM12 Chapter 12 Top Exam Questions & Answers, 100% Accurate. 
 
 
*Figure 12.1-Pic on test-Transposed pairs - -2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - -A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooti...
BICSI TDMM12 Chapter 13. Top Exam Questions and answers, 100% Accurate. Rated A+ 
 
 
The first step on a project should be a review of the _________ from the previous project. - -lessons learned (13-4) 
 
In project management, an organization breakdown structure (OBS) is used to answer the questio...
Voorbeeld 1 van de 2 pagina's
In winkelwagenBICSI TDMM12 Chapter 13. Top Exam Questions and answers, 100% Accurate. Rated A+ 
 
 
The first step on a project should be a review of the _________ from the previous project. - -lessons learned (13-4) 
 
In project management, an organization breakdown structure (OBS) is used to answer the questio...
BICSI TDMM12 Chapter 4. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Work area components include: - -Telecommunications outlet/connector, Work area cable (cord) MUTOA, WAP, NIC (4-1) 
 
In modular jack connections, the acronym 8P8C stands for: - -8-position, 8-contact (4-2) 
 
Figure 4.1 ...
Voorbeeld 2 van de 5 pagina's
In winkelwagenBICSI TDMM12 Chapter 4. Top Questions & Answers, 100% Accurate. Graded A+ 
 
 
Work area components include: - -Telecommunications outlet/connector, Work area cable (cord) MUTOA, WAP, NIC (4-1) 
 
In modular jack connections, the acronym 8P8C stands for: - -8-position, 8-contact (4-2) 
 
Figure 4.1 ...
BICSI TDMM12 Chapter 24. Top Exam Questions & Answers, Graded A+ 
 
 
Residential cabling consisting of a minimum of one 4-pair CAT5e (or higher) balanced twisted-pair cable and one 75-ohm Series 6 coaxial cable is classified as: - -Grade 1 (24-2) 
 
______ residential cabling is required to support...
Voorbeeld 1 van de 2 pagina's
In winkelwagenBICSI TDMM12 Chapter 24. Top Exam Questions & Answers, Graded A+ 
 
 
Residential cabling consisting of a minimum of one 4-pair CAT5e (or higher) balanced twisted-pair cable and one 75-ohm Series 6 coaxial cable is classified as: - -Grade 1 (24-2) 
 
______ residential cabling is required to support...
BICSI TDMM12 Chapter 19. Exam Questions and answers, 100% Accurate. 
 
 
ESS stands for - -Electronic Safety & Security (19-1) 
 
*Risk formula - -Risk = (Threat x Vulnerability)/Countermeasures (test) (19-7) 
 
The science of EAC is a means of regulating access to specific: - -Physical Space, Resou...
Voorbeeld 1 van de 3 pagina's
In winkelwagenBICSI TDMM12 Chapter 19. Exam Questions and answers, 100% Accurate. 
 
 
ESS stands for - -Electronic Safety & Security (19-1) 
 
*Risk formula - -Risk = (Threat x Vulnerability)/Countermeasures (test) (19-7) 
 
The science of EAC is a means of regulating access to specific: - -Physical Space, Resou...
BICSI TDMM12 Chapter 23, Top Exam Questions and answers. Graded A+ 
 
 
Two categories of public telephones= - -Coin telephones, Noncoin telephones (23-2) 
 
Advantages of booths: - -Max privacy, Min. noise interference, Seating capability, Weather protection (not cost) (23-2) 
 
**FCC has changed T...
Voorbeeld 1 van de 2 pagina's
In winkelwagenBICSI TDMM12 Chapter 23, Top Exam Questions and answers. Graded A+ 
 
 
Two categories of public telephones= - -Coin telephones, Noncoin telephones (23-2) 
 
Advantages of booths: - -Max privacy, Min. noise interference, Seating capability, Weather protection (not cost) (23-2) 
 
**FCC has changed T...
BICSI TDMM12 Chapter 15, Top Exam Questions & Answers, 100% Accurate. Graded A+ 
 
 
Two technologies in paging systems - -Centrally amplified systems, Distributed amplified systems (15-3) 
 
Jet airplane takeoff noise level = - -Exceeds 100 dB (15-7) 
 
Doctors exam room noise level = - -55 dB (15-...
Voorbeeld 1 van de 2 pagina's
In winkelwagenBICSI TDMM12 Chapter 15, Top Exam Questions & Answers, 100% Accurate. Graded A+ 
 
 
Two technologies in paging systems - -Centrally amplified systems, Distributed amplified systems (15-3) 
 
Jet airplane takeoff noise level = - -Exceeds 100 dB (15-7) 
 
Doctors exam room noise level = - -55 dB (15-...
BICSI Practice Test-RETAKE Questions and answers, 100% Accurate. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a -...
Voorbeeld 2 van de 11 pagina's
In winkelwagenBICSI Practice Test-RETAKE Questions and answers, 100% Accurate. VERIFIED. 
 
 
The 2 main considerations concerning the existing cabling are? - -Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a -...
BICSI RTPM 002 section 1 Site Survey, Top Questions and answers, 100% Accurate. Rated A+ 
 
 
Pathway Considerations - -In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - -most expensive system, ha...
Voorbeeld 1 van de 3 pagina's
In winkelwagenBICSI RTPM 002 section 1 Site Survey, Top Questions and answers, 100% Accurate. Rated A+ 
 
 
Pathway Considerations - -In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - -most expensive system, ha...
Stuvia-klanten hebben meer dan 700.000 samenvattingen beoordeeld. Zo weet je zeker dat je de beste documenten koopt!
Je betaalt supersnel en eenmalig met iDeal, creditcard of Stuvia-tegoed voor de samenvatting. Zonder lidmaatschap.
Samenvattingen worden geschreven voor en door anderen. Daarom zijn de samenvattingen altijd betrouwbaar en actueel. Zo kom je snel tot de kern!
Je krijgt een PDF, die direct beschikbaar is na je aankoop. Het gekochte document is altijd, overal en oneindig toegankelijk via je profiel.
Onze tevredenheidsgarantie zorgt ervoor dat je altijd een studiedocument vindt dat goed bij je past. Je vult een formulier in en onze klantenservice regelt de rest.
Stuvia is een marktplaats, je koop dit document dus niet van ons, maar van verkoper PassPoint02. Stuvia faciliteert de betaling aan de verkoper.
Nee, je koopt alleen deze samenvatting voor $36.49. Je zit daarna nergens aan vast.
4,6 sterren op Google & Trustpilot (+1000 reviews)
Afgelopen 30 dagen zijn er 98502 samenvattingen verkocht
Opgericht in 2010, al 14 jaar dé plek om samenvattingen te kopen